The SR series cables range from .034 - .250 in diameter. All of the Semi-Rigid Cable used are MIL-17C qualified, with tin plated copper outer conductor. The SR series cables are typically custom built assemblies and formed to your specifications. These assemblies are capable of frequencies up to 50 GHz with precision connectors .
Features
MIL-C-17 Qualified
Build & Bend to Drawing
Tight Tolerances
DC-50 GHz
Applications
Switch Matrix
Test Fixture
Instrumentation
Semi-Rigid Standard Connectors
SR086
SR141
SR250
2.4 mm to 50 GHz*
•
2.92 mm (K) to 40 GHz*
•
3.5 mm to 34 GHz*
•
•
SMA to 26.5 GHz
•
•
7 mm to 18 GHz
•
Type N to 18 GHz
•
•
TNC
•
Typical Insertion Loss
Attenuation (max.) vs. Frequency (GHz)
SR086
SR141
SR250
Conn. Loss dB
Straight Assy. SWR (x.xx:1)
dB/ft
dB/m
dB/ft
dB/m
dB/ft
dB/m
0.512
UHF
0.14
0.46
0.08
0.26
0.05
0.15
0.02
1.04:1
0.900
0.19
0.62
0.11
0.35
0.06
0.21
0.02
1.05:1
1.000
L
0.20
0.65
0.11
0.37
0.07
0.22
0.02
1.900
0.28
0.92
0.16
0.53
0.10
0.32
0.03
1.10:1
2.000
S
0.29
0.94
0.17
0.55
0.10
0.33
0.03
3.000
0.36
1.17
0.21
0.68
0.13
0.42
0.04
4.000
C
0.41
1.36
0.24
0.80
0.15
0.51
0.04
1.15:1
6.000
0.51
1.69
0.31
1.01
0.20
0.65
0.06
8.000
X
0.60
1.96
0.36
1.19
0.24
0.78
0.07
1.20:1
10.000
0.67
2.21
0.41
1.35
0.27
0.89
0.08
1.25:1
12.400
0.76
2.49
0.47
1.54
0.31
1.03
0.08
14.000
Ku
0.81
2.67
0.51
1.66
0.34
1.12
0.09
1.30:1
18.000
0.94
3.10
0.59
1.95
0.41
1.34
0.11
20.000
K
1.00
3.30
0.64
2.09
0.12
22.000
1.06
3.49
0.68
2.22
0.13
26.500
1.19
3.90
0.77
2.51
0.15
1.35:1
28.000
Ka
1.23
4.03
0.79
2.60
0.16
1.40:1
30.000
1.28
4.21
0.83
2.73
0.17
32.000
1.33
4.37
0.18
38.000
1.48
4.86
0.22
1.45:1
40.000
1.53
5.02
0.25
50.000
mm
1.76
5.78
0.32
1.50:1
Semi-Rigid Electrical Data
SR086
SR141
SR250
Maximum Frequency
Limited by Connector Interface
Impedance
50 ohm, nominal
Velocity of Propagation
69%, nominal
Time Delay
1.47 ns/ft (4.82 ns/m)
Capacitance
29.0 pF/ft (95.1 pF/m), nominal
Semi-Rigid Mechanical Data
SR086
SR141
SR250
Outer Conductor Outer Diam.
0.086 in
(2.20 mm), nominal
0.141 in
(3.58 mm), nominal
0.250 in
(6.35 mm), nominal
Bend Radius
0.500 in
(12.70 mm), nominal
0.750 in
(19.05 mm), nominal
1.250 in
(31.75 mm), nominal
Operating Temperature
-85 to 257 °F (-65 to +125 °C)
-85 to 212 °F
(-65 to +100 °C)
Weight
1.36 lbs/100ft
(2.02 kg/100m)
3.14 lbs/100ft
(4.67 kg/100m)
9.90 lbs/ft
(14.70 kg/100m)
Outer Conductor
Sn Plated Copper Tube
Dielectric
PTFE
Inner Conductor
Ag-plated Cu-Clad SST
Ag-plated Cu
Standard Connectors:
SR086: 1.85mm, 2.4mm, 2.92mm, 3.5mm, SMA
SR141: 3.5mm, 7mm, SMA, Type N
SR250: TNC, Type N
Other connectors available upon request.