Co-axial
Cable Insertion and Return Loss Measurement
Contents:
- What
is return loss
- Equipment
required to measure return-loss of a co-axial cable
- Measurement
of Co-axial cable losses
- Insertion loss measurement
- Return loss measurement
- The
relation between VSWR and Return Loss
(Conversion formulas)
- Glossary
of terms
- References
- What
is Return Loss:
Return loss is a measure of VSWR (Voltage
Standing Wave Ratio), expressed in decibels (db). The return-loss is caused
due to impedance mismatch between two or more circuits. For a simple cable
assembly, there will be a mismatch where the connector is mated with the
cable. There may be an impedance mismatch caused by nick or cuts in a cable.
At microwave frequencies, the material properties as well as the dimensions of
the cable or connector plays important role in determining the impedance match
or mismatch. A high value of return-loss denotes better quality of the system
under test (or device under test). For
example, a cable with a return loss of 21 db is better than another similar
cable with a return loss of 14 db, and so on.
- Equipment required to measure return-loss of
a co-axial cable:
A co-axial cable is chosen to measure the return-loss for study purpose.
Typically, for a device or a system, return-loss is measured at the input or
at the output. The following equipment are used to measure the return loss of
a co-axial cable at microwave frequencies:
- Frequency
source
- Network
Analyzer (either a scalar network analyzer or a vector network analyzer)
- Detector
with calibration source.
- Reflection
bridge
- Co-axial
Short
- Cable
under test (this could be any device under test)
- A
10dB attenuator (optional, but recommended).
- The Measurement of Co-axial cable losses:
The measurement process consists of
calibrating the test set-up for insertion and return-loss. If you have dual
channel network analyzer, both insertion and return losses can be measured
simultaneously. You can also measure insertion and return losses separately as
is done here.
3.a Insertion loss Measurement:
Step
1. Set the sweep source to the required frequency range. Make sure that the
output of the sweep source is within the desired amplitude limits, otherwise, it
may saturate the detector head and any measurements taken would not be accurate.
You may use an attenuator at the output of the sweep source to mitigate any
problem that may arise due to mismatch between the cable under test and the
sweep source. It is recommended to use a 10 dB attenuator for this purpose.
For
example, you can set the values as below:
Sweep
frequency (measurement frequency): 100MHz – 2.3 GHz
Sweep
power: 12 dBm
Note:
Also, make sure that you are measuring same impedance. For example, if the cable
is 50Ohm, and the Sweep generator output is 75 Ohm, you need to use a 50 to 75
Ohm impedance matching device.
Step
2: Calibrate the test system by connecting as shown in the figure 1, bypassing
the cable under test. Calibration is nothing but setting a reference line taking
all stray measurement errors into consideration.
Step
3: Now you have done the equipment calibration, connect the
cable as shown in the figure 2, without disturbing any other parameters such as
sweep power output or the attenuator value. The trace in the network analyzer
display now shows the Insertion loss of the cable against the frequency.
3.b Return loss Measurement:
Step
1. The sweep source is already set during insertion loss measurement. You may
use an attenuator at the output of the sweep source to mitigate any problem that
may arise due to mismatch between the cable under test and the sweep source. It
is recommended to use a 10 dB attenuator for this purpose.
For
example, you can set the values as below:
Sweep
frequency (measurement frequency): 100MHz – 2.3 GHz
Sweep
power: 12 dBm
Note:
Also, make sure that you are measuring same impedance. For example, if the cable
is 50Ohm, and the Sweep generator output is 75 Ohm, you need to use a 50 to 75
Ohm impedance matching device.
Step
2: Calibrate the test system by connecting as shown in the figure 3, bypassing
the cable under test. Calibration is nothing but setting a reference line taking
all stray measurement errors into consideration. You need to short the bridge
port as shown in the figure. For better accuracy, Open/Short method is can be
used. In Open/Short method, you calibrate for the system by using both an Open
and a Short instead of only a Short used in this example.
Step
3: Now you have done the equipment calibration, connect the
cable as shown in the figure 4, without disturbing any other parameters such as
sweep power output or the attenuator value. The end of the cable needs to be
terminated with a 50 Ohm termation.
The
Graph:
The
trace in the network analyzer display in figure 5 shows the Insertion Loss and
Return Loss of the cable against the frequency. Note that the Insertion Loss is
typically low in the desired band of frequencies, and the Return Loss is high.
Typically, Insertion loss will of a fraction of a db (for co-axial cable) and
the Return loss is 10 dB or more.
The
relation between VSWR and Return Los
Article courtesy: Tutorialsweb.com